• DC 3-Wire Model , Shielded , M12.
No. | Description | Specification |
1. | Cylinder type sensing head size |
M12 |
2. | Type |
Shielded |
3. | Sensing method |
Inductive type |
4. | Sensing distance |
2 mm -10% to +10% |
5. | Setting distance |
0 to 1.6 mm |
6. | Differential distance |
10% Max. of sensing distance |
7. | Sensing object |
Ferrous metal (Sensitivity lowers with non-ferrous metals.) |
8. | Standard sensing object |
Iron 12*12*1mm |
9. | Response frequency |
DC: 1.5 kHz (average) |
10. | Power supply voltage |
12 to 24 VDC ripple(p-p) :10% Max. |
11. | Operating voltage range |
10 to 40 VDC |
12. | Current consumption |
13 mA Max |
13. | Control output (Output type) |
NPN voltage-current output |
14. | Control outpu (Switching capacity) |
0 to 200 mA |
15. | Indicator |
Operation indicator(red) |
16. | Operation mode |
NO |
17. | Protective circuit |
Surge suppressor Output short-cut protection Power supply reverse polarity protection |
18. | Ambient temperature |
Operating: -40 to 85 ℃ Storage: -40 to 85 ℃ (with no icing or condensation) |
19. | Ambient humidity |
Operating: 35 to 95% RH Storage: 35 to 95% RH (with no condensation) |
20. | Temperature influence |
+/- 10% Max. of sensing distance in temperature range of -25 to +70 CEL +/- 15% Max. of sensing distance in temperature range of -40 to +85 CEL (As the basis for sensing distance of 23CEL) |
21. | Voltage influence |
+/- 1% Max. of sensing distance in rated voltage range +/- 15%. (As the basis for sensing distance at standard power voltage) |
22. | Insulation resistance |
50 M OHM Min. at 500VDC between charged parts and the case |
23. | Dielectric strength |
1000 VAC 50/60 Hz for 1 minute between charged parts and the case |
24. | Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
25. | Shock resistance |
1000m/s2 for 10 times each in X, Y, and Z directions |
26. | Degree of protection |
IEC60529: IP67 Company standard: Oil-proof |
27. | Applicable standard (EC Directive (Low Voltage Directive) ) |
EN60947-1 EN60947-5-2 |
28. | Applicable standard (EC Directive (EMC)) |
EMI: EN60947-5-2 Emission Enclosure: CISPR11 Group 1 class A EMS: EN60947-5-2 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Burst: IEC61000-4-4 CE marking: Equipped |
29. | Applicable standard (CCC mark) |
Not equipped |
30. | Connection method |
Pre-wired models (Cable length: 2 m) |
31. | Weight (Packed state) |
approx. 75 g |
32. | Material (case) |
Brass nickel plating |
33. | Material (sensing surface) |
PBT |
34. | Material (clamping nuts) |
Brass nickel plating |
35. | Material (toothed washer) |
Iron zinc plating |
36. | Accessories |
Instruction manual |